MAKSEL / TRINITY K2 · ORION 7 PLUS
Usage and care guide
Essential steps for Trinity K2 and Orion 7 Plus, from assembly to care.
This guide summarizes the information in the user manuals of both models as short, practical steps.
First setup and assembly
Trinity K2
- Fit the shaft tubes together and tighten them.
- Wrap the search coil cable around the shaft.
- Plug the cable connector into the search coil input on the control unit. The headphone and charging inputs are also on the control unit.
- Switch the detector on with the on/off switch on the back and wait until the LOADING bar is full.
- Carry out ground adjustment before you start searching.
Orion 7 Plus
- Join the shaft carrying the control unit to the other tubes at the points marked with arrows.
- Wind the search coil cable around the shaft in a spiral. Adjust how tightly you wind it so the cable is neither too long nor too short.
- Plug the connector at the end of the cable into the back of the control unit and tighten its screw.
- When you switch the detector on, the All Metals screen appears. Carry out ground adjustment before you start searching.
Charging and battery care
Trinity K2
The battery is inside the system housing. Charging a fully empty battery takes approximately 5 hours.
- Connect the charger to the detector’s charging input.
- While charging, the charger LED is red; it turns green when charging is complete.
- Unplug the adapter when charging is complete.
- The LED is also green if no battery is connected, the battery is full or there is a fault.
- Charge the detector when the remaining battery indicator drops to one segment or to zero.
- Do not charge the battery in wet or damp conditions; do not leave it in the sun or in heat.
- Do not use any charger other than the original one.
- If you will not use the detector for a long time, store it with a fully charged battery.
Orion 7 Plus
It uses a lithium-ion battery. Charging an empty battery takes approximately 4 hours; a fully charged battery provides approximately 8 hours of use.
- Before use, check the battery indicator in the upper right corner of the screen. It shows a value from 1 to 9; 9 means full.
- Switch the detector off and charge it only with the charger made for Orion 7 Plus. Charging takes longer while the detector is on.
- While charging, the adapter LED is red; it turns green when charging is complete.
- When the indicator drops below 1, the detector shows a warning and switches off.
- It is normal for the adapter to become warm while charging. If it becomes too hot to touch, unplug it and let it rest for a while; if this happens often, contact authorized service.
Ground adjustment
Ground adjustment adapts the detector to the soil you are searching. Carry it out before you start searching.
Trinity K2
Automatic ground adjustment
- Switch the detector on and wait until the LOADING bar is full.
- Press the G (ground adjustment) key.
- Hold the search coil about 5 cm above the soil and swing it at least 1 metre to the right and left. The numbers on the screen change.
- When you hear a beep, automatic ground adjustment is complete. For a more even adjustment, repeat it a few times at the same height.
- Press the middle key to start searching in General search mode.
- Do not adjust indoors or where metal is present. For the first adjustment, keep large metal objects at least about 2 metres away.
- On filled ground, lower the sensitivity in the Settings menu before adjusting.
- If constant sound or interference continues in General search, move to another spot and repeat ground adjustment.
Orion 7 Plus
Automatic adjustment
- Press Ground, and with automatic adjustment selected, press ENTER.
- Slowly raise the search coil to about 40 cm and press ENTER.
- Lower the coil to about 10 cm above the ground and press ENTER. When adjustment is complete, the screen confirms that the ground has been adjusted.
- If the screen asks you to raise the coil again, raise it and repeat the procedure.
- Move the coil gently left and right to make sure the bars do not move, then press ENTER to start searching.
Manual adjustment
- Open the ground adjustment menu with Ground and select manual adjustment.
- Raise the coil to about 40 cm above the ground and press ENTER.
- Lower the coil until it is 10–15 cm above the ground and watch whether the left bar or the right bar moves.
- Raise the coil to 40 cm again; if the left bar moves, press − once, and if the right bar moves, press + once.
- Repeat the last two steps until the bars no longer move, then press ENTER to switch to searching.
- Press − and + only while the coil is raised.
- Lower the sensitivity value on highly mineralized soil; raise it when searching for small metal objects.
Search modes at a glance
Trinity K2
- General search: Always begin your first search in this mode.
- Fast search: Opened with the up arrow key on the General search screen.
- Discrimination mode: Opened with the down arrow key once you are sure of the target.
Orion 7 Plus
- All Metals: The screen shown when the detector is switched on and settings are complete; it receives signals from all metals without discrimination.
- Graphic Discrimination: Opened with the Disc. key; signals are shown graphically in four main categories.
- FAST: Opened with the FAST key after ground adjustment; metal ranges can be enabled or disabled for the search.
Choosing a search coil
The frequency depends on the fitted search coil. Change the coil to change the frequency; the two frequencies are not used at the same time.
Trinity K2
- 26 × 32 cm coil (14 kHz): Recommended for small metals and single coins (for example in Fast search). With this coil, sweep about 5 cm above the ground.
- 36 × 41 cm coil (7 kHz): Recommended for deep searches.
After changing the coil
- Connect the new coil’s cable to the control unit.
- Open the Settings menu with M and run coil calibration.
- After calibration, carry out ground adjustment again.
Orion 7 Plus
- 26 × 32 cm coil (14 kHz): Recommended for small metals and single coins.
- 36 × 41 cm coil (7 kHz): Recommended for deep searches.
Correct sweeping technique
- Decide on your search direction.
- Move the search coil left and right in front of you in a rhythmic arc, advancing so that no area is left unscanned.
- Advance at normal walking pace or slower.
- Keep the coil at a constant height.
- Trinity K2: 5–10 cm above the ground.
- Orion 7 Plus: 15–20 cm above the ground.
- Swinging the coil up and down does not upset the ground adjustment, but a coil held higher may detect at a somewhat shorter distance.
Trinity K2
- Trinity K2: Always keep the coil parallel to the ground; a coil that is not parallel can give incorrect results.
Pinpointing and depth estimation
These steps help you confirm where a signal is and estimate the approximate depth of the target.
Trinity K2
Confirming a signal
- When you receive a signal in General search, the bars on the screen move. The point where a bar reaches its highest level is the centre of the target.
- Move the detector aside, raise the coil about 30 cm and press the middle (enter) key.
- Lower the coil to about 5 cm above the ground and carefully pass it over the signal spot again.
- Once you are sure of the target, switch to Discrimination mode with the down arrow key, reset with the middle key and pass slowly over the signal point. Repeat several times to be sure.
Pinpointing
- When you receive a signal in Fast search, press and hold the middle key.
- Pass the coil over the signal area again. The screen shows the most intense point of the signal, which is where the target lies.
Orion 7 Plus
Following a signal
On the All Metals screen, a rising red bar on the right and rising sound volume give an idea of how close or how large the target is. The graph in the middle of the screen shows the signal for a short time.
Approximate depth estimation (both models)
- Move the search coil away from the signal area. Do not start the depth check over the target.
- Open the depth detection screen: on K2, choose depth detection in the Settings menu with M; on Orion 7 Plus, choose it in the device settings menu with MENU.
- Raise the coil about 40 cm above the ground and press the confirm key (the middle key on K2, ENTER on Orion 7 Plus).
- Lower the coil and pass it over the signal spot again. Remember the distance between the points where the signal starts and ends.
- Enter this distance as the diameter value with the arrow keys and press the confirm key. The estimated depth appears on the screen.
- If two metal objects lie close together, the signal of the one passed over last applies. Keep this in mind with consecutive signals.
Care, storage and safety
- Use the detector between 0 and +45 °C; do not use it outside this range.
- Do not use it in wet weather. Do not expose the detector to rain, snow, hail or frost. Only the search coil can be immersed; the front panel/control unit must stay out of the water.
- Store all parts in a dry place; do not store them in damp conditions.
- Protect the search coil from hard impacts.
- Use only the original battery, charger and search coil. Non-original parts can damage the detector and harm the user.
- For repair and maintenance, contact Maksel authorized service only. Any intervention outside Maksel authorized service voids the warranty.
- The detector, battery and accessories are made of recyclable materials. Do not put them in household waste at the end of their life; recycle them in line with the waste and environmental regulations of your country.
- These detectors are made for civil use. They must not be used for military purposes or in situations that could endanger human life.
Any questions?
Contact our team with questions about use, charging or care.
